Timer thermostats

Techno WPT R

Discontinued This product is no longer on sale. The manual remains available for existing owners.

  • Code 578148
Manual languages
Download PDF
Techno WPT R

Product description

This product is designed according to EN 60730-2-9 and EN60730-2-7, ETSI EN 301 489-1, ETSI EN 300 200-2 standards, in compliance with the applicable EC directives, and made in Italy.

Warning

We strictly recommend to install this de-vice according to the safety regulations in force in the European Community and local countries.  The mains circuit brea-ker must be off before carrying out any electrical connections.

Technical specifications

Power supply
Alkaline Batteries 2x1,5V LR6 (Type AA)
Battery life
>1year
Maximum capacity of the contacts
5A(1A) 250VAC
Type of action
1B
Operating frequency
868.2 Mhz
Category of the receiver
2
Duty cycle of the transmitter
< 1%
Capacity
300 m outdoors, 20 m indoors
Type of antenna
internal, on PCB
Maximun ambient temperature
50°C
Temperature display range
0°C÷39°C
Temperature regulation range
5°C÷35°C
Temperature resolution
0,1°C
Temperature probe
NTC 100KΩ@25°C
Temperature differential
from 0,1°C to 2,0°C (std. 0,2°C)
Degree of protection
IP20
Insulation class
Type II (double insulation)
Pollution degree
2
Software
class A
Heat and fire resistance
Category D
Storage temperature
-25÷60°C
Rated impulse withstand voltage
2,5kV
Installation
on wall
External sensor input (optional)
NTC 10KΩ@25°C
Class ErP I (ON/OFF adjustment)
EU 811/2013

Installation

Place this device far from any heat source or air flow, at about a 1,5mt height from the floor. Open the device pushing the clip on the base right side (Fig.1-A) then rotate the front cover leftward (Fig.1-B) and lift slightly to unfasten it (Fig.1-C).

Fig. 1-A
Fig. 1-B, Fig. 1-C

Fix the base on to the wall, using the horizontal (Fig.2, A-A or A-B) or the vertical (Fig.2, C-C) holes.

Fig. 2, A-A, A-BFig. 2, C-C

Insert the batteries in their compartment on the display board as described (Fig.4).

Fig. 4

Close the device proceeding like in Fig.1, reversing the operations order: match the left side of the two parts (Fig.1-C) then rotate the front cover rightward (Fig.1-B) until the clip on the base clacks (Fig.1-A).

BATTERIES REPLACEMENT

When the battery symbol Batterie scariche on the display flashes (batteries out of power) take care of their replacement. Please proceed as described in the installation instructions (Fig.1 and Fig.4). Re-assemble the front cover back to the base before performing any operation on the control.

Description of controls and operation

Command keys are accomplished on a four position ring each one identified by the arrows Freccia sinistra Freccia destra Freccia su Freccia giù, an additional key in the middle, hereafter named OK and four keys more: Menu (Copy), Prog (Paste), Mode, Esc. Press the ring exactly on the arrows to avoid multiple keys activations. Press OK key in the middle. Use arrow keys to modify time and temperature values or select the available options. OK key is generally used to confirm the settings.

Fig. 5

FIRST START

Setting the clock (Fig.6)

  • Set the 24H or 12H by Freccia su Freccia giù then OK.
  • Set the hours by Freccia su Freccia giù then OK.
  • Set the minutes by Freccia su Freccia giù then OK.
  • Set the day of the week by Freccia sinistra Freccia destra then OK. The device switches to OFF mode. Pair with the radio receiver from the installer menu.
    Fig. 6

OFF MODE (Fig.7)

The display shows OFF and the clock, the anti-frost function is active.
Press Mode to browse active modes (Manual Comfort, Manual Economy, Automatic mode). Press Esc to switch between active modes and OFF.

Fig. 7

MANUAL MODE (Fig.8)

Press Freccia su or Freccia giù to change and save the temperature set-points:
MAN = Comfort temperature.
MAN ECO = Economy temperature.

Fig. 8

AUTOMATIC MODE (Fig.9)

Fig. 9

The set-point temperature (t1, t2, t3) depends on the saved time program and changes automatically along the day.

TIME PROGRAM (Fig.10)

Press Prog, the display shows the set temperature updated at the current half-hour, PROG flashes.
Press OK to select t1, t2 or t3.
Press Freccia su Freccia giù to select the day of the week.
Press Freccia sinistra Freccia destra to move along the hours without changing settings.
To make a daily program copy choose the day you want to duplicate and press COPY then move along the week until the desired one and press PASTE.
To change the set-point temperatures t1, t2 and t3:

  • Press Mode and change the value T1 by  Freccia su Freccia giù.
  • Press Mode and change the value T2 by Freccia su Freccia giù.
  • Press Mode and change the value T3 by Freccia su Freccia giù. Press Mode to quit and go back to the time program. Press Esc to quit and go back to automatic mode.
    Fig. 10

SEASON MODE: WINTER Inverno

Comfort temperature is greater than Economy (t1>t2>t3). When Tamb < Tset heating turns on Riscaldamento

SEASON MODE: SUMMER Estate

Comfort temperature is smaller than Economy (t1<t2<t3).  When Tamb > Tset cooling turns on Raffrescamento

SETTINGS MENU (Fig.11)

Press Menu to enter the settings menu. Press Freccia sinistra Freccia destra to browse the available options.

  • Press Freccia su Freccia giù to select the season mode (Summer/Winter),
  • Press OK to set the clock (like before);
  • Press Freccia su Freccia giù to select (Celsius/Farhenheit) degrees;
  • Press Freccia su Freccia giù to select the language;
  • Press Freccia su Freccia giù to set the desired backlit brightness. Press Esc to quit the menu.
    Fig. 11

INSTALLER MENU (Fig.12)

In OFF mode, hold OK for 10 seconds to enter the menu:
Press Freccia sinistra Freccia destra to browse the available options.

  • Antifrost = Set antifrost threshold (standard 6.0°C);
  • Hysteresis = Switching differential (standard 0.2°C);
  • Offset = temperature calibration (standard 0.0°C);
  • NTC Internal / NTC External ;
  • Hold OK to reset and restore factory settings.
  • Confirm with OK to pair the device with the radio receiver and wait for the conclusion of the procedure. If the communication is activated, RADIO OK will appear on the display; otherwise RADIO ERR will appear. Press Esc to quit the menu.
    Fig. 12

HUMIDITY DISPLAY OPTION (AVAILABLE ONLY ON WPT RH MODELS)

In one of the operating modes, press OK to switch between the set temperature or room humidity display in the top right of the screen (Fig.13).

Fig. 13
Download PDF

Request information

If you had problems with the installation or have remarks about the manual, you can contact Customer Service by filling in the form below.

Fields marked with * are required.

Get the manual by email

Techno WPT R

We will immediately send you an email with the PDF manual attached.